No dead volume
A conical, thread end without seams for both the female and male thread of the connector or ball valve guarantees a connection with no dead volume. This in turn ensures that no bacteria can become lodged, media do not crystallise and dirt particles cannot adhere.
Save norm PDFHigh temperature compatibility
Our versatile connector types are the ideal solution if you have to work with aggressive media at very high temperatures. The outstanding chemical properties, high operational reliability and special connection principles meet all the requirements for working with high-temperature media.
Save norm PDFRoHS
The raw materials used by emtechnik meet the requirements of the RoHS directive 2002/95/EC, RoHS directive 2011/65/EU and RoHS del. directive 2015/863/EU. That means they contain no lead, cadmium, chromium VI, mercury or the flame retardants PBB and PDBE or the plasticisers DEHP, BBP, DBP and DIBP, and that such materials are also not used anywhere in the production process.
Save norm PDFHigh Purity
emtechnik has had a clean room to DIN EN ISO 14644-1 class 5 since 1997 (since 2018 also class 7). This facility makes it possible to clean and assemble our products in a contamination-free atmosphere.
All of our products certified to conform to the high-purity standard undergo a carefully monitored production process at our works: For preparation for further processing in the clean-room, products we manufacture using either injection moulding or by mechanical means are first pre-cleaned in an ultrasound bath with an oil separator and a DI bath. In the clean-room itself, the products are cleaned a second time and dried in vacuum conditions. The products are then final assembled and quality controlled by specially trained employees.
All clean-room products are placed in special double-welded packaging for safe transport. This packaging is also filled with class 5.0 nitrogen.
We can pre-treat our products on request according to their intended application to achieve a silicon-free or oil and grease-free surface.
Save norm PDFUSP Class VI
The identified materials are available on request with approvals corresponding to the guidelines of USP Class VI (pharmaceutical approval). The U.S. Pharmacopeial Convention (USP) is a non-commercial organisation that develops the standards for the quality of medications and other medical products. The comprehensive tests of the biological responsiveness of elastomers, plastics and polymers with direct or indirect patient contact. The standards are divided into six classes. Class VI includes the strictest tests and is widely used and accepted in the pharmaceutical and medical products industry.
Save norm PDFSterile
PVDF and PFA are also suitable for hot steam sterilisation – the indispensable requirement for absolute sterility. PVDF is autoclavable with no concerns at 134 °C or can be sterilised with γ radiation while fully retaining its mechanical properties (maximum dosage 25 - 50 kGy). PVDF is non-toxic in the range <150°C and does not provide any breeding ground for microorganisms. The surface of PVDF behaves very similarly to glass.
Save norm PDFSuitable for use in food products
The term "Suitable for use in food products" summarises materials that meet the provisions of the FDA and/or the European regulations of EC 1935/2004.
Many of our materials are available with approvals in line with the provisions of EU law or the FDA (U.S. Food and Drug Administration) regarding suitability for use in food products. The FDA is the regulatory agency of the United States of America for monitoring of foods and approval of drugs. It monitors the safety and effectiveness of human and animal medicines, biological products, medical products, foodstuffs and radiation-emitting devices. This applies to both products produced in the USA and imported products.
EC 1935/2004 defines uniform requirements in regards to packaging materials and objects that come in contact with food either directly or indirectly. They are intended to protect human health as well as consumer interests while ensuring that the products that are used can be sold everywhere in the European area.
Save norm PDFElectrically conductive
To prevent electrostatic charges from accumulating, the high-performance plastics PP, PVDF and PTFE are equipped with electrically conducting particles, which therefore gives them a very low surface resistance of < 10³ Ω and < 10² Ω. For media that are sensitive to UV radiation, it is important for the materials to be dyed solid black to block all UV light. PVDF-EL and PTFE-EL materials are also UV-resistant. Our products in these materials thus ensure maximum safety combined with impressive chemical resistance property.
Save norm PDFADI Free
In order to avoid any contamination with animal constituents, such as BSE pathogens, in the production process, emtechnik offers products made from plastics classified as ADI-free.
Save norm PDFResistance to aggressive media
Plastics can come into contact with a very wide range of different liquids and chemicals during use. emtechnik products have long-term resistance to aggressive media in numerous applications and are also resistant in aggressive environments.
Save norm PDFReference standards (extract)
DIN 13 | Metric ISO threads |
DIN 168 | GL knuckle threads |
DIN EN 1333 | Pressure and temperature data |
DIN EN 12266 | Technical delivery conditions for fittings |
DIN 32676, ISO 2852, BS 4825 | Size, diameter and locking brackets for Tri-Clamp connectors |
DIN 3852 | Sealing collar and recess on male and female threads |
DIN 19213 | Connection dimensions for effective pressure measuring devices |
DIN EN 1092, DIN 2527, ASME B16.5 | Connection dimensions for flanges |
DIN EN ISO 80369-7 | Small-bore connectors for liquids and gases in healthcare applications |
DIN EN ISO 228 | Cylindrical pipe threads |
DIN ISO 2768 | General tolerances |
EN 837 | Connection sleeve for pressure transducer |
EN 10204 | Types of test certificates |
ISO 10931 | PVDF plastic pipe systems |
ASME 1.20.1 | NPT thread |
Certificates
ATEX
ATEX, which stands for French "ATmosphère EXplosible", is the brief description of European Directive 2014/34/EU. It governs placing of explosion protected electrical and mechanical devices, components and protective systems on the market. Since July 1, 2003 it has applied to all new devices and protective equipment.
A potential ignition source arises through internal function or external effects. Both of these can be ignored for fitting from emtechnik.
Directive 97/23 EC, Pressurised Vessel Regulations
Our products, valves, ball valve, flow meters and special fittings fall under diagram 8 of the Pressurised Vessel Regulations based on fluid class, pressure, nominal diameters and volume. In the area of article 4 paragraph 3.
Vacuum suitability of products
In the helium tightness test method, the test object is evacuated and charged with helium. Since helium has a very small molecular size, it can penetrate even through very small leaks, which means it can be detected very quickly.